Lab 1100C High Temperature Microwave Calculation Furnace Device
Description
HAMiLab-AS1500 Microwave calculation furnace is SYNOTHERM standard microwave high temperature device specially used in lab. It applies to all kinds of materials’ sintering, burning, firing, compounding, calculating, melting other heat treatment in the air atmosphere.
Features
-Adopt the industry-grade microwave source to ensure the furnace’s long time continuous steady running.
-Achieve super-fast heating, save a lot holding time, increase experiment efficiency exponentially;
-Microwave output power adjustable freely, no gear limitation, to achieve accurate temperature control curve;
-Adopt imported high-precision IR thermometer to measure directly the temperature of the sample.
-Be equipped with embedded micro-computer control system, offer manually operation, automatically operation, constant temperature operation three modes, shifted freely.
-All kinds of original crucibles insulation structures available for choice, no pollution to materials.
-It can deal with different kinds of materials, with good commonality;
-Set with the corrosion-resistant exhaust passage, exhaust rapidly the gas produced in the heating process.
-Touch screen display operation, equipped with windows operation system, able to be connected with PC; Capable of set store many temperature control curves. Store automatically running records, compatible with printer; real time display the temperature control curve, to achieve the dynamic monitor of the heating process;
-Safe reliable microwave shield design, multi-ply protection from microwave leakage.
Application field
-Powered particles materials’ calcination systhesis;
-Finished products’ sintering;
-Calculating, sintering, firing melting experiments.
Technical specification
Technical specification |
|
Model |
HAMiLab-AS1500 |
Voltage |
AC 220 plus/minus 10V; 50Hz/60Hz, |
Rated power |
3 kw |
Microwave output power |
0.2-1.2 KW continuously variable |
Microwave frequency |
2.45GHz plus/minus 25MHz |
Max working temperature |
1100 Celsius degree |
Temperature measuring way |
thermocouple |
Temperature accuracy |
plus/minus 0.5% |
Atmosphere system |
air |
Max loading space (LxWxH) |
150X100X70mm |
Cooling |
Wind |
Protection Safety |
Anode over voltage, anode over current, anode power surpass, electromagnet watchdog, magnetron temperature, external interlock. |
Control System |
PLC (18 sections of temperature control), embedded system connected to laptop via USB, with data storage printing functions. |
Microwave Leakage |
< 1mW/cm2 (Safety standard < 5mW/cm2) |
Site area |
0.8 m2 |