Lab High Control Precision Anaerobic Incubator Equipped with Gloves
A. Structural characteristics
a. Using 7 inch large screen true color touch screen microcomputer control type, can accurately and intuitively control the incubator temperature and other parameters. The system uses PLC as the core controller, supplemented by high precision temperature sensor, oxygen sensor, temperature control module, analog module, high control precision, good stability, high safety; Humanized human-machine interface, convenient for operators to monitor process data in real time.
b. The imported oxygen sensor is used, and the oxygen content of the operating room is directly displayed on the touch screen, which is convenient to observe whether the internal anaerobic state is reached.
c. Can do anaerobic culture, can also do micro-oxygen culture (oxygen concentration: 0-10%).
d. With USB interface, the memory can store 6 months of data.
e. Anaerobic sampling room and anaerobic operating room are one-click automatic gas displacement.
f. The see-through window cover can be removed as a whole to facilitate the placement of larger instruments or thorough cleaning.
g. The operating room is equipped with ultraviolet germicidal lamps, which can effectively avoid bacterial contamination.
h. Standard lighting, power socket.
i. The operation room is equipped with a deoxygenated catalytic device and uses a highly efficient palladium catalyst to avoid frequent activation.
j. The gas displacement in the operating room adopts fully automatic control technology, which is protected by positive and negative pressure.
k. The sampling (aisle) room has the function of automatic vacuuming and automatic pressure preservation.
l. Sample transfer: Hull type operation, in and out of the first gas exchange, and then into the incubator, can transfer 40 90mm flat petri dishes at a time, both the operation of the access channel, can also be used to transfer flat petri dishes.
m. The unique design of the oil bottle pressure relief brake protects the internal positive pressure, prevents air leakage, and prevents the positive pressure from overstretching the glove.
n. Fitted with leakage protector.
o. Oil-free vacuum pump is used.
p. The dual foot switch can directly control the inflation and exhaust of the operation room with the foot, which solves the trouble that the operator is not convenient to free his hand to touch the controller's inflation and exhaust switch buttons when he is operating with gloves.
B. Technical parameter
Type parameter |
LAI-3T-N |
Temperature control range for use of incubator (C) |
Room temperature +3~60 |
Incubator temperature uniformity (C) |
<±1 |
Incubator temperature fluctuation (C) |
<±0.3 |
Anaerobic class |
Oxygen content in operating room <0.1% |
Anaerobic state formation time of the sampling chamber |
< 10 minutes |
The sampling chamber is formed in an anaerobic manner |
Vacuum + gas displacement (nitrogen + mixture) |
Anaerobic state formation time in the operating chamber |
< 70 minutes |
The operating chamber is formed in an anaerobic manner |
Vacuum + gas displacement (nitrogen + mixture)+ micro-flow mixture replenishment and control |
Operation room anaerobic environment maintenance time |
Operating room with no supplement of trace gas mixture, >13 hours |
Control of anaerobic formation |
Anaerobic sampling room and anaerobic operating room are one-click automatic gas displacement |
Incubator size (cm)W×D×H |
42×30×50 can hold 100 90mm flat petri dishes |
Incubator internal Volume (L) |
63 |
Sampling chamber size (cm)W×D×H |
40 *32 *33 |
Sampling chamber channel size (cm)W×H |
27.5 *29.5 |
Operation room size (cm)W×D×H |
95 * 68 * 75 |
Overall dimensions (cm)W×D ×H |
145 * 74 * 142 |
Packing box size (cm)W x D x H |
154 * 87 * 155 |