BET Porosity Surface Area Analyzer Instrument Price


BET Analyzer

Surface Area Analyzer


Main features:

Analysis ability up to 12 samples/ hour;

Dynamic chromatography, in line with the national standard;

Free of standard sample, completely eliminate the influence of standard sample;

High resolution, high stability, high cost performance;

BSD-BET400 automatic fast surface analyzer - performance parameters

 

Test principle:

To sample tube continuous access to a certain proportion of carrier gas (He) and adsorption gas mixed gas (N2), under the low temperature of liquid nitrogen (environment) to make the sample adsorption equilibrium, then the liquid nitrogen cup down, use hot wind to help to take off the function to make the sample tube to heat up, thereby rapidly the sample of the adsorption of N2 molecule stripping out, mixed gas concentration changes, The adsorption capacity of the sample to be measured was obtained by the concentration detector. Because the desorption peak is sharper and can be well integrated, the first choice is preferred to evaluate the initial gas adsorption amount.


Surface Area Analyzer 

 

Features and advantages:

  High efficiency: the world's most efficient specific surface test system; BSD-BET400 with BSD-AD8 eight-station pre-processing machine, the analysis capacity can reach 12 samples/hour, and includes 30min pre-processing; BET method: dynamic Chromatography test conforms to the national standard, taking into account the high efficiency of the test; Exempt standard sample: Exempt standard sample, completely eliminate the influence of standard sample and reduce test cost; High stability: Dynamic chromatography has unique high stability and is suitable for industrial quality control; High resolution: For small and medium specific surface samples, it is suitable for rapid analysis of specific surface of battery materials, metal powders, organic powders and other materials. Constant-temperature volumetric tube (patent): A volumetric tube in a constant-temperature state, which is not affected by the ambient temperature and is a guarantee of high stability; Liquid nitrogen temperature detection (patent): The liquid nitrogen temperature detection technology eliminates the purity factor of liquid nitrogen Influence;

 

Porosity Analyzer 

 

Model: BSD-BET400

Net weight: 35Kg

Size: 55 cm * 44 cm * 73 cm

Voltage: AC220v± 5V, power less than 500W



Technical specification:

1.Test method: BET dynamic chromatographic method for surface analysis, solid standard sample reference method for surface analysis; Test accuracy: The test resolution and stability are world-leading, and the relative error is less than ±1% (standard sample);

 2.Test range: The test range is wide, and it can measure substances with a specific surface area above 0.01m2/g, which can meet the test of the specific surface area of all powder substances and porous substances; sample types: powder, granule, fiber and sheet materials, etc.

 3.Purging treatment: It can be used for in-situ purging and pretreatment of the instrument, or it can be equipped with a BSD-AD8 eight-station pretreatment machine to increase the utilization rate of the analysis station and improve the test efficiency;

 4.Wind-heat assisted desorption: It has the only program-controlled wind-heat desorption device in China to ensure sharp and rapid desorption peaks and reduce background errors; (patent name: specific surface meter with blowing and heating function patent number: ZL200920110451.5)

 5.Detector zero drift suppression: It has the only detector constant temperature system in China, so that the drift of the detector within 10 minutes is less than 0.1mV, ensuring the accuracy and stability of the test results; (Patent name: Gas constant temperature device and specific surface meter Patent number: ZL200920110454. 9)

 6.Gas purification cold trap: It has the only gas purification cold trap in China, which improves the gas purity by more than one order of magnitude;

(Patent name: Gas purification cold trap and specific surface meter Patent No.: ZL200920110450.0)

 7.Best sample tube: Best sample tube ensures the accuracy of the test while making the sample tube easy to load. It is not limited to powder sample testing; (Patent name: U-shaped sample tube for surface area meter Patent No. 200920110452.X)

 8.Test stability: Large screen 5 inches LCD liquid crystal display, each mechanical part action instructions, so that the instrument working state parameters software and hardware can be displayed at the same time, even if the software is not opened, the instrument state can be accurately grasped, making the instrument more stable;

 9.Test gas circuit: Using low-temperature nitrogen adsorption dynamic chromatography, unique parallel gas circuit at home and abroad, eliminates external influences such as ambient temperature, humidity, atmospheric pressure, etc., does not need to be vacuumed, and the laboratory conditions are relatively loose; (the bottom factor of high stability) );

 10.Data processing: The software is a self-developed high-precision data processing system, with a high sampling frequency of 100 Hz, and fully automatic control; it has a fully functional specific surface data processing capability;

 11.Instrument hardware: hardware is purchased globally, all key components are imported parts, which have undergone rigorous testing and are suitable for frequent testing;

 12.After-sales equipment: The company is responsible for on-site installation, commissioning, and operation training, and implements a system of regular customer visits. The after-sales service is thoughtful, the customer is wide, and the reputation is high.

 

 

(Optional) Eight-station purge pretreatment machine: Introduction to instrument functions

  For the rapid surface area analyzer of dynamic chromatography, in order to obtain the true surface area results of the material, the sample needs to be pretreated by heating and purging before the test. The dynamic chromatography full-automatic rapid surface analyzer independently developed and produced by Bester has the function of in-situ heating pretreatment. After loading the sample, you only need to install the sample tube in the test position, perform heating pretreatment first, and then directly test it. There is no need to disassemble and transfer the sample tube during the process.

However, in the case of heavy test tasks, in-situ processing will cause the instrument test position to be occupied and reduce the utilization rate of the test position. Therefore, Bester launched the BSD-AD8 purge pretreatment machine. The sample can be purged on the pretreatment machine first, and then transferred to the instrument for testing, so that the test efficiency is increased to more than twice the original.

 

 

Performance index:

Porosity Analyzer 


Model: BSD-AD8

Size: 35cm*39cm*47cm

Net weight: 25Kg

voltage: AC220v±5v, power 600W

1. Supporting equipment: 3H-2000A, 3H-2000BET-A, BSD-BET400 automatic surface analyzer;

2. Processing number: 8 processing positions, divided into 2 groups * 4 processing positions; 2 groups of processing positions can work independently, Do not affect each other

 3. Cooling position: 8 cooling positions, the sample tube after high temperature treatment can be moved to the cooling position to return to normal temperature before disassembly and assembly;

4. Automatic timing: different processing temperature and processing time can be set;

5. Purge temperature: room temperature~400℃, temperature control accuracy ±1℃;

6. Purge gas flow: 2 channels*80ml/min;

7. Touch screen temperature control: a large touch screen thermostat makes temperature control more accurate, and the heating process is visualized;

8. Quick disassembly and assembly: the sample tube is quickly plugged and sealed, and the operation is simple and convenient;

 

(Optional) Main parameters of BSD-LN mobile pollution-free liquid nitrogen pump

1. Automatic liquid nitrogen output, only need to turn on the switch to output liquid nitrogen, the liquid nitrogen output rate is 2L/min;

2. It is suitable for cryogenic tanks of all calibers in the domestic and foreign markets (patent protection point of Bester instruments);

3. The standard liquid nitrogen container has a volume of 30L and a diameter of 50mm;

4. Equipped with ultra-quiet universal wheel base, ultra-quiet movement without noise;

5. Special liquid nitrogen pump pipes and insulation materials that are still soft at the temperature of liquid nitrogen are used to ensure convenient operation and long service life;

6. Two-level safety guarantee, eliminating the overpressure hazards of similar functional products on the market at home and abroad (Best Instrument patent protection point);

7. Compared with similar products at home and abroad, there is no need to inject air into the cryogenic container, and there is no problem of liquid nitrogen pollution (patent protection point of Bester instrument);

8. No need for AC power, easy to move;

9. The automation can be improved and upgraded to realize the docking with automatic control equipment such as automatic liquid nitrogen filling, automatic constant liquid nitrogen surface, ultra-low temperature and constant temperature, etc.;

Automatic Specific Surface Area Analyzer


Standard configuration

Name

Specification

Unit

No.

Pump head

The pumping speed 2 l/min

set

1

Mobile base

Silent mode

pcs

1

Liquid nitrogen container

30L

pcs

1

 


 